Sample Mean (x̄): Average of sample data
Population Mean (μ₀): Hypothesized value under null hypothesis
Sample Standard Deviation (s): Measure of variability in sample
Standard Error: s/√n, measures variability of sample mean
Degrees of Freedom: df = n - 1
- State hypotheses: H₀: μ = μ₀ vs H₁: μ ≠, >, or < μ₀
- Check conditions: Normality assumption, independence
- Calculate test statistic: t = (x̄ - μ₀)/(s/√n)
- Find p-value: Based on t-distribution with df = n-1
- Make decision: Compare p-value to α and draw conclusion
Given: n = 25, x̄ = 980, s = 50, μ₀ = 1000, α = 0.05
This is a two-tailed test since we're testing if the mean differs from 1000
H₀: μ = 1000 (manufacturer's claim is accurate)
H₁: μ ≠ 1000 (manufacturer's claim is inaccurate)
Sample size n = 25 < 30, so we need normality assumption
Assuming population is normally distributed
t = (x̄ - μ₀)/(s/√n)
t = (980 - 1000)/(50/√25)
t = -20/(50/5) = -20/10 = -2.0
df = n - 1 = 25 - 1 = 24
Two-tailed test: p-value = 2 × P(T₂₄ ≥ |−2.0|) = 2 × P(T₂₄ ≥ 2.0)
From t-table with df = 24: P(T₂₄ ≥ 2.0) ≈ 0.0285
p-value = 2 × 0.0285 = 0.057
Since p-value (0.057) > α (0.05), fail to reject H₀
At α = 0.05, there is insufficient evidence to reject the manufacturer's claim that bulbs last 1000 hours on average.
• T-test Formula: t = (x̄ - μ₀)/(s/√n) when σ is unknown
• Degrees of Freedom: df = n - 1
• Two-tailed P-value: Multiply tail probability by 2
Given: n = 16, x̄ = 78.5, s = 8, μ₀ = 75, α = 0.01
H₀: μ ≤ 75 (new method doesn't increase scores)
H₁: μ > 75 (new method increases scores)
Sample size n = 16 < 30, so normality assumption needed
t = (78.5 - 75)/(8/√16)
t = 3.5/(8/4) = 3.5/2 = 1.75
df = 16 - 1 = 15
Right-tailed test: p-value = P(T₁₅ ≥ 1.75)
From t-table with df = 15: P(T₁₅ ≥ 1.75) ≈ 0.050
Since p-value (0.050) > α (0.01), fail to reject H₀
At α = 0.01, there is insufficient evidence to conclude that the new teaching method increases test scores.
• Right-tailed P-value: p-value = P(T ≥ observed value)
• Strict Alpha: α = 0.01 requires stronger evidence
• Conservative Decision: Higher α level would reject H₀
Given: n = 20, x̄ = 8.5, s = 2.5, μ₀ = 10, α = 0.05
H₀: μ ≥ 10 (defects are at least 10 per unit)
H₁: μ < 10 (defects are less than 10 per unit)
Sample size n = 20 < 30, so normality assumption needed
t = (8.5 - 10)/(2.5/√20)
t = -1.5/(2.5/4.472) = -1.5/0.559 = -2.68
df = 20 - 1 = 19
Left-tailed test: p-value = P(T₁₉ ≤ -2.68)
Since t-distribution is symmetric: P(T₁₉ ≤ -2.68) = P(T₁₉ ≥ 2.68)
From t-table with df = 19: P(T₁₉ ≥ 2.68) ≈ 0.0075
Since p-value (0.0075) ≤ α (0.05), reject H₀
There is sufficient evidence to conclude that the mean number of defects is less than 10 per unit.
• Left-tailed P-value: p-value = P(T ≤ observed value)
• Symmetric Property: Use symmetry for negative t-values
• Decision Rule: Reject H₀ if p-value ≤ α
Given: n = 100, x̄ = 52, s = 10, μ₀ = 50
t = (52 - 50)/(10/√100) = 2/(10/10) = 2/1 = 2.0
df = 100 - 1 = 99
z = (52 - 50)/(10/√100) = 2/(10/10) = 2/1 = 2.0
(We use s as estimate for σ since σ unknown)
T-test: p-value = 2 × P(T₉₉ ≥ 2.0) ≈ 2 × 0.024 = 0.048
Z-test: p-value = 2 × P(Z ≥ 2.0) = 2 × 0.0228 = 0.0456
With df = 99, t-distribution is very close to standard normal
As n increases, t-distribution approaches normal distribution
For n > 30, t-test and z-test yield nearly identical results
t-statistic = 2.0, p-value ≈ 0.048 (reject H₀ at α = 0.05)
z-statistic = 2.0, p-value ≈ 0.046 (reject H₀ at α = 0.05)
Results are nearly identical for large samples
• Large Sample Convergence: As n → ∞, t-distribution → normal distribution
• Practical Equivalence: For n > 30, t-test and z-test give similar results
• Conservative Approach: Use t-test regardless of sample size
Given: n = 5, x̄ = 12, s = 4, μ₀ = 10, α = 0.05
t = (12 - 10)/(4/√5) = 2/(4/2.236) = 2/1.789 = 1.12
df = 5 - 1 = 4
T-test: For α = 0.05, two-tailed, df = 4: t₀.₀₂₅ = ±2.776
Z-test: For α = 0.05, two-tailed: z₀.₀₂₅ = ±1.96
T-test MOE = t₀.₀₂₅ × (s/√n) = 2.776 × 1.789 = 4.97
Z-test MOE = z₀.₀₂₅ × (s/√n) = 1.96 × 1.789 = 3.51
T-test: |t| = 1.12 < 2.776, so fail to reject H₀
Z-test: |z| = 1.12 < 1.96, so fail to reject H₀
Both lead to same conclusion, but t-test is more conservative
Both tests fail to reject H₀, but t-test has wider critical region
T-test accounts for uncertainty in estimating σ with small sample
Using z-test with small samples would be too liberal
• Small Sample Uncertainty: t-distribution has heavier tails to account for σ estimation
• Conservative Testing: t-test is more appropriate for small samples
• Margin of Error: t-test has larger MOE than z-test for same confidence level
Population Mean (μ): True mean in the population being studied
Sample Mean (x̄): Observed mean in the sample
Sampling Distribution: Under H₀, t ~ t-distribution(df = n-1) when conditions are met
Effect Size: |x̄ - μ₀|/s, standardized measure of practical significance
Random Sampling: Data must come from a random sample
Independence: Observations must be independent (n ≤ 10% of population)
Normality: Either population is normally distributed OR n ≥ 30 (CLT)
Unknown σ: Population standard deviation is unknown (using s instead)